![Much Much](https://i.ytimg.com/vi/2ZhW1omPxLI/maxresdefault.jpg)
Load Combinations are a critical aspect of design. It is important to ensure you are correctly applying the relevant design load combinations to ensure the minimum design requirements of your local design code are being met. Here, SkyCiv has released a summary of the design combinations integrated in our Structural Analysis Software for engineers to use as a reference. We have included the load combos for ASCE 7-10, AS/NZ 1170, ACI, NBCC and EN 1990.
ASCE 7-10 Load Combinations
ASCE 7 10 is a design code for the United States; focussing on the minumum requirements for structural design in the US. With this design standard, it provides the recommended load factors and load combinations to be applied to each of the load types (wind, snow, dead etc..) and is particularly useful for design codes such as AISC 360 - Structural Steel Buildings. This design standard comes with two provisions;
- ASD - Allowable Strength Design
- LRFD - Load and Resistance Factor Design
Below are the summarized load combination factors for ASCE 7-10 based on their provisions:
Design Code Equation | Design Code Comment | SkyCiv Equation | SkyCiv Comment |
---|---|---|---|
1.4D | Eq. 2.3.2.1 | 1.4G | - |
1.2D + 1.6L + 0.5(Lr or S or R) | Eq. 2.3.2.2 | 1.2G + 1.6QL + 0.5QS | The load type 'Snow' is sub-categorized into 'snow', 'roof live', and 'rain'. Selecting this load combination will automatically create 3 load combination equations due to the use of 'or' in the equation specification. |
1.2D + 1.6(Lr or S or R) + (L or 0.5W) | Eq. 2.3.2.3 | 1.2G + 1.6QS + QL 1.2G + 1.6QS + 0.5QW | Due to the presence of 'or' in two places of this load combination, this generates 6 load equations. SkyCiv has separated this into two load combinations (for the L or 0.5W options) which generates 3 load equations each. |
1.2D + 1.0W + L + 0.5(Lr or S or R) | Eq. 2.3.2.4 | 1.2G + QW + QL + 0.5QS | The load type 'Snow' is sub-categorized into 'snow', 'roof live', and 'rain'. Selecting this load combination will automatically create 3 load combination equations due to the use of 'or' in the equation specification. |
1.2D + 1.0E + L + 0.2S | Eq. 2.3.2.5 | 1.2G + QL + 0.2QS + E | - |
0.9D + 1.0W | Eq. 2.3.2.6 | 0.9G + QW | - |
0.9D + 1.0E | Eq. 2.3.2.7 | 0.9G + E | - |
Design Code Equation | Design Code Comment | SkyCiv Equation | SkyCiv Comment |
---|---|---|---|
D | Eq. 2.4.1.1 | G | - |
D + L | Eq. 2.4.1.2 | G + QL | - |
D + (Lr or S or R) | Eq. 2.4.1.3 | G + QS | The load type QS 'Snow' is sub-categorized into 'snow', 'roof live', and 'rain'. Selecting this load combination will automatically create 3 load combination equations due to the use of 'or' in the equation specification. |
D + 0.75L + 0.75(Lr or S or R) | Eq. 2.4.1.4 | G + 0.75QL + 0.75QS | The load type QS 'Snow' is sub-categorized into 'snow', 'roof live', and 'rain'. Selecting this load combination will automatically create 3 load combination equations due to the use of 'or' in the equation specification. |
D + (0.6W or 0.7E) | Eq. 2.4.1.5 | G + 0.6QW G + 0.7E | Due to the presence of an 'or' in the load combination, two load combination eqations are required to represent them. Since 'wind' and 'seismic' are not linked by a load type, two separate equations are given by SkyCiv, instead of auto-generating equations in the case of the QS snow load type. |
D + 0.75L + 0.75(0.6W) + 0.75(Lr or S or R) | Eq. 2.4.1.6a | G + 0.75QL + 0.45QW + 0.75QS | The load type QS 'Snow' is sub-categorized into 'snow', 'roof live', and 'rain'. Selecting this load combination will automatically create 3 load combination equations due to the use of 'or' in the equation specification. |
D + 0.75L + 0.75(0.7E) + 0.75S | Eq. 2.4.1.6b | G + 0.75QL + 0.75QS + 0.525E | Only one load equation is required to represent this load combination. Despite the presence of QS 'Snow' load type, only one equation is generated by SkyCiv for the 'snow' sub-type. |
0.6D + 0.6W | Eq. 2.4.1.7 | 0.6G + 0.6QW | - |
0.6D + 0.7E | Eq. 2.4.1.8 | 0.6G + 0.7E | - |
Nov 20, 2017 - 2D Frame analysis. Enhanced: Added new support for pattern load combinations. Enhanced: Added a new Quasi load combination type.
AS/NZ 1170 Load Combinations
AS/NZS 1170 is a design standard for the minimum design loads for buildings and other structures in Australia and New Zealand. The focus of this standard is to provide structural engineers with load combinations for design.
The AS 1170 load combinations can be divided into a number of criteria, depending on what is being designed for:
Design Code Equation | Design Code Comment | SkyCiv Equation | SkyCiv Comment |
---|---|---|---|
Ed,stb = [0.9G] | Net Destabilizing: Permanent action only (does not apply to prestressing forces) | 1.35G | SPC: Permanent Destabilizing |
Ed,stb = [1.35G] | Net Stabilizing: Permanent action only (does not apply to prestressing forces) | 0.9G | SPC: Permanent Stabilizing |
Ed,stb = [1.2G,1.5Q] | Permanent and imposed action | 1.2G + 1.5QL | ULS: Permanent & Imposed. |
Ed,stb = [1.2G, Wu, ψc,Q] | Permanent, wind and imposed action | 1.2G + ψ2,1QL + QW | ULS: Permanent, Wind & Imposed. The imposed action factor represented by the psi is determined by the type of QL that this equation acts against. |
Ed,stb = [1.2G, Su,ψc,Q] | Permanent action, actions given in Clause 4.2.3 and imposed action. | 1.2G + ψ0,3QL + QS | ULS: Permanent, Other, & Imposed. The imposed action factor represented by the psi is determined by the type of QL that this equation acts against. |
Design Code Equation | Design Code Comment | SkyCiv Equation | SkyCiv Comment |
---|---|---|---|
Ed = [1.35G] | Permanent action only (does not apply to prestressing forces) | 1.35G | Identical to Ed,dst. |
Ed = [1.2G,1.5Q] | Permanent and imposed action | 1.2G + 1.5QL | Identical to Ed,dst. |
Ed = [1.2G,1.5ψlQ] | Permanent and long term imposed action | 1.2G + 1.5ψ1QL | ULS: Permanent & Long-term Imposed. The imposed action factor represented by the psi is determined by the type of QL that this equation acts against. |
Ed = [0.9G, Wu] | Permanent and wind action reversal | 0.9G + Qw | ULS: Permanent, Wind |
Ed = [G, Eu, ψc,Q] | Permanent, earthquake and imposed action | G + ψ2,nQL + E | SPC: Permanent, Earthquake & Imposed |
Ed = [1.2G, Su,ψc,Q] | Permanent action, actions given in Clause 4.2.3 and imposed action. | 1.2G + ψ0,3QL + QS | Identical to Ed,dst. |
SkyCiv Equation | SkyCiv Comment |
---|---|
G + ψ0,1QL | SLS Permanent and Short-term Imposed |
G + ψ1QL | SLS Permanent and Long-term Imposed |
ACI 318 Load Combinations
ACI 318 is a US concrete design standard released by the American Concrete Institute specifying the minimum design loads and load factors for concrete structures. Fundamentally, all structures/structural members should possess design strengths at all sections at least equal to the required strengths calulated for the factored loads and forces in combinations.
Chapter 9 of the code details the strength and serviceability load combination requirements of structural members:
Design Code Equation | Design Code Comment | SkyCiv Equation | SkyCiv Comment |
---|---|---|---|
U = 1.4D | Eq. 9-1 | 1.4G | - |
U = 1.2D + 1.6L + 0.5(Lr or S or R) | Eq. 9-2 | 1.2G + 1.6QL + 0.5QS | The load type QS 'Snow' is sub-categorized into 'snow', 'roof live', and 'rain'. Selecting this load combination will automatically create 3 load combination equations due to the use of 'or' in the combination. |
U = 1.2D + 1.6(Lr or S or R) + (1.0L or 0.5W or 0.8W) | Eq. 9-3. Referencing R9.2-Required Strength (b): Where W is based on service-level wind loads, 0.8W shall be used in place of 0.5W in Eq. 9-3. | 1.2G + 1.6QS + ψ1QW 1.2G + 1.6QS + QL | This load combination involves 3 terms. As in the combination for Eq. 9-2, QS will create 3 equations to account for the 'or' statement for 'snow', 'roof live', and 'rain'. The third term is either L (live) or W (wind). SkyCiv represents this by 2 separate load combinations (each generating 3 equations). To account for service level requirements in R9.2(b), users can select load types 'Wind: strength' or 'Wind: service level' to apply factors 0.5 or 0.8 (respectively) to their load groups. |
U = 1.2D + (1.0 or 1.6)W + 1.0L + 0.5(Lr or S or R) | Eq. 9-4. Referencing R9.2-Required Strength (b): Where W is based on service-level wind loads, 1.6W shall be used in place of 1.0W in Eq. 9-4. | 1.2G + γuQW + QL + 0.5QS | This load combination involves 4 terms. As in the combination for Eq. 9-2, QS will create 3 equations to account for the 'or' statement for 'snow', 'roof live', and 'rain'. The second term for W (wind) has two possible factors. To account for service level requirements in R9.2(b), users can select load types 'Wind: strength' or 'Wind: service level' to apply factors 1.0 or 1.6 (respectively) to their load groups. |
U = 1.2D + (1.0 or 1.4)E + 1.0L + 0.2S | Eq. 9-5. Referencing R9.2-Required Strength (c): Where E is based on service-level forces, 1.4E shall be used in place of 1.0E in Eq. 9-5. | 1.2G + γaE + QL + 0.2QS | This load combination involves 4 terms. As 'snow' is explicitly mentioned in the combination, QS will only generate one equation. The second term for E (seismic) has two possible factors. To account for service level requirements in R9.2(c), users can select load types 'Seis: strength' or 'Seis: service level' to apply factors 1.0 or 1.4 (respectively) to their load groups. |
U = 0.9D + (1.0 or 1.6)W | Eq. 9-6. Referencing R9.2-Required Strength (b): Where W is based on service-level wind loads, 1.6W shall be used in place of 1.0W in Eq. 9-6. | 0.9G + γuQW | This load combination involves 2 terms. Only 1 equation is generated. The second term for W (wind) has two possible factors. To account for service level requirements in R9.2(b), users can select load types 'Wind: strength' or 'Wind: service level' to apply factors 1.0 or 1.6 (respectively) to their load groups. |
U = 0.9D + (1.0 or 1.4)E | Eq. 9-7. Referencing R9.2-Required Strength (c): Where E is based on service-level forces, 1.4E shall be used in place of 1.0E in Eq. 9-7. | 0.9G + γaE | This load combination involves 2 terms. Only 1 equation is generated. The second term for E (seismic) has two possible factors. To account for service level requirements in R9.2(c), users can select load types 'Seis: strength' or 'Seis: service level' to apply factors 1.0 or 1.4 (respectively) to their load groups. |
NBCC 2010 - Canadian Load Combinations
NBCC 2010 is the Canadian provision for the design and construction new buildings. It provides minimum technical provisions for the design and construction of new buildings. For the purposes of Canadian load combinations, Part 4 of the design code provides specifications for limit states design:
Design Code Equation | Design Code Comment | SkyCiv Equation | SkyCiv Comment |
---|---|---|---|
Principal Loads: 1.4D | Table 4.1.3.2.A - Case 1 | 1.4G | - |
Principal Loads: (1.25D or 0.9D) + 1.5L Companion Loads: 0.5S or 0.4W | Table 4.1.3.2.A - Case 2 | γuG + 1.5QL γuG + 1.5QL + 0.5QS γuG + 1.5QL + 0.4QW | Since there is an 'or' in the companion load, when considering no companion load as an option, a total of 3 equations are generated. SkyCiv represents this with 3 load combinations. The factor for the dead load may be either 1.25 (unfavorable) or 0.9 (favorable). SkyCiv offers you the option to assign your load groups to the 'Dead: unfavorable' or 'Dead: favorable' load types which will apply the factors accordingly. Each SkyCiv load combination here will only generate one equation. |
Principal Loads: (1.25D or 0.9D) + 1.5S Companion Loads: 0.5L or 0.4W | Table 4.1.3.2.A - Case 3 | γuG + 1.5QS γuG + 1.5QS + 0.5QL γuG + 1.5QS + 0.4QW | As above. |
Principal Loads: (1.25D or 0.9D) + 1.4W Companion Loads: 0.5L or 0.5S | Table 4.1.3.2.A - Case 4 | γuG + 1.4QW γuG + 1.4QW + 0.5QL γuG + 1.4QW + 0.5QS | As above. |
Principal Loads: 1.0D + 1.0E Companion Loads: 0.5L + 0.25S | Table 4.1.3.2.A - Case 5 | G + E G + E + 0.5QL + 0.25QS | This case generates 2 equations when considering the principal loads alone, or the principal loads and companion loads together. SkyCiv represents these by two separate equations. |
EN 1990:2002 EC0, EN 1991 EC1 Eurocode Load Combinations
The Eurocodes are a set of standards for how structural design should be conducted within the European Union. EN 1990:2002 (ECO) sets out the basis of structural design whereas EN 1991 (EC1) specifies the actions on structures. In conjunction, these two documents provide a methodology for the Eurocode load combinations of actions for limit states design. The ultimate limit states for loss of equilibrium (EQU), internal failure (STR), ground deformation (GEO) need to be checked together with accidental/seismic (ALS) and servicibility limit states (SLS) when appropriate.
Permanent Actions (Unfavourable) | Permanent Actions (Favourable) | Leading Variable Action | Accompanying Variable Actions |
---|---|---|---|
1.10Gk,j | 0.90Gk,j | 1.5Qk,1 (0 when favourable) | 1.5ψ0,iQk,1 (0 when favourable) |
SkyCiv's Equation | SkyCiv's Comment |
---|---|
0.9G | ULS: EQU (Favourable). All dead (G) load types will be given a 0.9 factor as this load combination is specifically for 'favourable' conditions. |
γGjG + 1.5QL + 1.5ψ0,1QS + 0.75QW + 0.9QT | ULS: EQU (Favourable/Unfavourable). Leading variable: Imposed loads QL. You may assign your permanent load groups as 'Dead: Unfavourable' (with factor 1.10) or 'Dead: Favourable' (with factor 0.9) load types. |
γGjG + 1.5QS + 1.5ψ0,1QL + 0.75QW + 0.9QT | ULS: EQU (Favourable/Unfavourable). Leading variable: Snow loads QS. You may assign your permanent load groups as 'Dead: Unfavourable' (with factor 1.10) or 'Dead: Favourable' (with factor 0.9) load types. |
γGjG + 1.5QW + 1.5ψ0,1QL + 1.5ψ0,1QS + 0.9QT | ULS: EQU (Favourable/Unfavourable). Leading variable: Wind loads QW. You may assign your permanent load groups as 'Dead: Unfavourable' (with factor 1.10) or 'Dead: Favourable' (with factor 0.9) load types. |
γGjG + 1.5QT + 1.5ψ0,1QL + 1.5ψ0,1QS + 0.75QW | ULS: EQU (Favourable/Unfavourable). Leading variable: Temperature loads QT. You may assign your permanent load groups as 'Dead: Unfavourable' (with factor 1.10) or 'Dead: Favourable' (with factor 0.9) load types. |
Permanent Actions (Unfavourable) | Permanent Actions (Favourable) | Leading Variable Action | Accompanying Variable Actions |
---|---|---|---|
1.35Gk,j | 1.00Gk,j | 1.5Qk,1 (0 when favourable) | 1.5ψ0,iQk,1 (0 when favourable) |
SkyCiv's Equation | SkyCiv's Comment |
---|---|
G | ULS: STR (Favourable). All dead (G) load types will be given a 1.0 factor as this load combination is specifically for 'favourable' conditions. |
1.35G + 1.5QL + 1.5ψ0,1QS + 0.75QW + 0.9QT | ULS: STR (Unfavourable). Leading variable: Imposed loads QL. All load group which have been assigned as a 'Dead' load type will be assigned the 'unfavourable' value (1.35) regardless of the subtype due to the single source principal. |
1.35G + 1.5QS + 1.5ψ0,1QL + 0.75QW + 0.9QT | ULS: STR (Unfavourable). Leading variable: Snow loads QS. All load group which have been assigned as a 'Dead' load type will be assigned the 'unfavourable' value (1.35) regardless of the subtype due to the single source principal. |
1.35G + 1.5QW + 1.5ψ0,1QL + 1.5ψ0,1QS + 0.9QT | ULS: STR (Unfavourable). Leading variable: Wind loads QW. All load group which have been assigned as a 'Dead' load type will be assigned the 'unfavourable' value (1.35) regardless of the subtype due to the single source principal. |
1.35G + 1.5QT + 1.5ψ0,1QL + 1.5ψ0,1QS + 0.75QW | ULS: STR (Unfavourable). Leading variable: Temperature loads QT. All load group which have been assigned as a 'Dead' load type will be assigned the 'unfavourable' value (1.35) regardless of the subtype due to the single source principal. |
Permanent Actions (Unfavourable) | Permanent Actions (Favourable) | Leading Variable Action | Accompanying Variable Actions |
---|---|---|---|
1.00Gk,j | 1.00Gk,j | 1.3Qk,1 (0 when favourable) | 1.3ψ0,iQk,1 (0 when favourable) |
SkyCiv's Equation | SkyCiv's Comment |
---|---|
G | ULS: GEO (Favourable). All dead (G) load types will be given a 1.0 factor as this load combination is specifically for 'favourable' conditions. |
G + 1.3QL + 1.3ψ0,1QS + 0.65QW + 0.78QT | ULS: GEO (Unfavourable). Leading variable: Imposed loads QL. |
G + 1.3QS + 1.3ψ0,1QL + 0.65QW + 0.78QT | ULS: GEO (Unfavourable). Leading variable: Snow loads QS. |
G + 1.3QW + 1.3ψ0,1QL + 1.3ψ0,1QS + 0.78QT | ULS: GEO (Unfavourable). Leading variable: Wind loads QW. |
G + 1.3QT + 1.3ψ0,1QL + 1.3ψ0,1QS + 0.65QW | ULS: GEO (Unfavourable). Leading variable: Temperature loads QT. |
Design Situation | Permanent Actions (Unfavourable) | Permanent Actions (Favourable) | Leading Accidental or Seismic Action | Accompanying Variable Action (Main) | Accompanying Variable Action (Others) |
---|---|---|---|---|---|
Accidental (Eq. 6.11a/b) | 1.00Gk,j | 1.00Gk,j | Ad | ψ1,1 or ψ2,1Qk,1 | ψ2,iQk,i |
Seismic (Eq. 6.12a/b) | 1.00Gk,j | 1.00Gk,j | γIAEk or AEd | - | ψ2,iQk,i |
SkyCiv's Equation | SkyCiv's Comment |
---|---|
G + A + ψ1QL + ψ2,1QS | ALS: ACC-a. Main accompanying variable action: Imposed loads QL |
G + A + ψ1QS + ψ2,1QL | ALS: ACC-a. Main accompanying variable action: Snow loads QS |
G + A + 0.2QW + ψ2,1QL + ψ2,1QS | ALS: ACC-a. Main accompanying variable action: Wind loads QW |
G + A + 0.5QT + ψ2,1QL + ψ2,1QS | ALS: ACC-a. Main accompanying variable action: Temperature loads QT |
G + A + ψ2,1QL + ψ2,1QS | ALS: ACC-b. Main and other accompanying variable actions equivalent |
G + E + ψ2,1QL + ψ2,1QS | ALS: SEI. |
Combination | Permanent Actions | Leading Variable Action | Accompanying Variable Actions |
---|---|---|---|
Characteristic | Gk,j | Qk,1 | ψ0,iQk,1 |
Frequent | Gk,j | ψ1,1Qk,1 | ψ2,iQk,1 |
Quasi-permanent | Gk,j | ψ2,1Qk,1 | ψ2,iQk,i |
SkyCiv's Equation | SkyCiv's Comment |
---|---|
G + QL + ψ0,1QS + 0.5QW + 0.6QT | SLS: Characteristic. Leading variable action: Imposed loads QL |
G + QS + ψ0,1QL + 0.5QW + 0.6QT | SLS: Characteristic. Leading variable action: Snow loads QS |
G + QW + ψ0,1QL + ψ0,1QS + 0.6QT | SLS: Characteristic. Leading variable action: Wind loads QW |
G + QT + ψ0,1QL + ψ0,1QS + 0.5QW | SLS: Characteristic. Leading variable action: Temperature loads QT |
G + ψ1QL + ψ2,1QS | SLS: Frequent. Leading variable action: Imposed loads QL |
G + ψ1QS + ψ2,1QL | SLS: Frequent. Leading variable action: Snow loads QS |
G + 0.2QW + ψ2,1QL + ψ2,1QS | SLS: Frequent. Leading variable action: Wind loads QW |
G + 0.5QT + ψ2,1QL + ψ2,1QS | SLS: Frequent. Leading variable action: Temperature loads QT |
G + ψ2,1QL + ψ2,1QS | SLS: Quasi-permanent. |
Tekla is delighted to bring you Tekla Tedds 2015. This latest release consolidates all the updates maintained users have received during the past year, along with some powerful new features:
New functionality for analyzing and designing steel beams to Eurocode. Engineers can now model and analyze a complete 2D frame and then design each beam, all within this single integrated calculation.
The 2D analysis calculation now includes an in-built load combination generator which means you can review multiple loading configurations simultaneously. Additional refinements have been made to the results and drawings.
Enhanced functionality for combining multiple calculations into a single report for submitting to clients or a checking authority.
Forget time consuming hand calculations and cumbersome spreadsheets.
Automate your repetitive structural and civil calculations with Tekla Tedds and transform the way you work.
- Access a broad library of structural and civil calculations.
- Use a single solution for all common elements & materials.
- Benefit from a simple and intuitive interface.
- Create transparent calculations that are easy to check.
- Compare different design options and make changes quickly.
- Produce consistent documentation.
- Enhance your Quality Assurance processes.
- Receive new and enhanced calculations and code updates regularly.
A simple solution for writing your calculations.
Have a specific requirement? Want to write your own calculations? No problem.
You don’t need to be a technical whiz to write custom calculations using Tedds.
![Tedds Load Combinations 2d Analysis Tedds Load Combinations 2d Analysis](https://teklatedds.support.tekla.com/sites/tedds/files/dita/images/tekla_tedds_2018/tekla_tedds_2018/Graphics/en-us/GUID-3B329A4E-36DD-46CD-9EC7-FF564C931EC8-publishing.png)
- Write, store and distribute your own custom calculations.
- Benefit from a range of powerful development tools.
- Create transparent calculations that are easy to check.
- Reduce the risk of errors associated with traditional calculation methods.
- Update your calculations at the touch of button.
- Store and access your calculations through the Tedds library.
- Distribute your calculations and share knowledge within your business.
One solution. Combine analysis and calculations with Tedds.
Still turning to complex analysis software for your everyday frame analysis? Why not do it in Tedds?
- Analyze frames such as trusses, cranked beams & portal frames.
- Visualize input and results graphically in real time.
- Link results to your Tedds calculations.
- Embed frame analysis into your bespoke calculations.
- Compile a single project document including notes and sketches.
- Avoid the need to use separate analysis software.
Professional project documents. Fully within your control.
Struggling to create professional project documentation? Use Tedds to create and customize high quality output, including structural calculations, sketches and notes.
- Create professional and transparent project documents.
- Work within Microsoft Word, a familiar and industry standard interface.
- Customize the look and feel, incorporating your company branding.
- Include multiple notes and sketches in your project document.
- Customize the level of detail in your output with ease.
- Submit a single electronic project document in formats such as PDF.
- Archive your calculations and store your jobs on your server.
REQUEST AN EVALUATION VERSION OF THIS SOFTWARE